News Center
synecom SF6 decomposition Transfer with Low-Cost

synecom SF6 decomposition Transfer with Low-Cost

In this paper, the flashover discharging experiment was carried out on epoxy resin surface in an SF6 atmosphere under pin-plate electrodes, with the electrodes distance from 5 mm to 9 mm. The concentration of seven characteristic gases was detected, indicating that the concentration of SOF2 and CF4 was the two highest, followed by SO2, CO2, SO2F2, CS2, and H2S. Based on the changes in the ...

[email protected]
News Detail
  • Services SF6 - Synecom

    L’impianto di «RIGENERAZIONE SF6» SEPARATION OF SF6 FROM INDUCED MIXTURES WITH N2 OR OTHER GAS. Reference activities for entities, companies, laboratories who, for their own targets, require a separation process of SF6 after a temporary use in blend with N2 or others. SF6 gas is returned to customers as “NEW” gas according to CEI60376.

    Get Price
  • Development of SF 6 decomposition gas sensor | Request PDF

    Gas sensors for detecting SF6 decomposition products have been pursued as low-cost instrumentation for detecting and locating faults in gas-insulated switchgear (GIS).

    Get Price
  • Theoretical study of the neutral decomposition of SF6 in the

    Aug 26, 2016 · In the presence of H 2 O and O 2, the dissociation products of SF 6 will decompose to form several main stable byproducts (i.e. SOF 2, SOF 4 and SO 2 F 2) in an electrical dischar

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    From the environmental and health points of view, it is necessary to mitigate and control the emissions of the decomposition products from SF 6 destruction processes because most of them (e.g. S 2 F 10, SF 4 and HF) are highly reactive, corrosive and toxic, and few of them are also potent GHGs. This article aimed to introduce the fully

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE Journals

    Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • Home - Synecom

    Synecom srl is synergy of experience and expertise developed in the field of HIGH TECHNOLOGICAL CONTENT SYSTEMS applied to the Energy, Chemistry, Oil Gas, Research, Waste Management and Waste Treatment sectors.

    Get Price
  • (PDF) Mechanism of Formation of SF6 Decomposition Gas

    Gas sensors for detecting SF6 decomposition products have been pursued as low-cost instrumentation for detecting and locating faults in gas-insulated switchgear (GIS).

    Get Price
  • (PDF) SF6 Decomposition Gas Sensor Based on GeP Monolayer: A

    In this paper, we adopted the first-principles calculations to investigate the sensing properties of the GeP monolayer to four SF6 decomposition gas molecules (H2S, SO2, SO2F2 and SOF2).

    Get Price
  • MicroPort CRM - Synecom™

    Synecom is a data transfer software for Holter Spiderview recordings (24 hours and up to 12 channels). With its embedded communication option, Synecom allows easy, cost-effective and secure sending and receiving of Holter recordings via an existing email, webmail or FTP connection.

    Get Price
  • Know How - Synecom

    +39 (035) 4376691 - [email protected] EMAIL. This website uses cookies to provide you with the best browsing experience. Find out more or adjust your settings. Accept.

    Get Price
  • Highly-efficient conversion of SF6 via an eight-electron

    Jun 01, 2020 · Here we report that the Li-SF 6 chemistry is able to deliver an unprecedented capacity of 20,000 mA h g c −1 with reduced polarization and excellent rate capability by using a low-cost, high-surface-area porous carbon as cathode host.

    Get Price
  • SF6 Gas Servicing Equipment – ENERVAC INTERNATIONAL ULC

    Due to the above reasons, SF6 is used mostly in applications that allow reclamation as opposed to using it on equipment that requires release of the gas, only to be re-filled with virgin SF6. ENERVAC produces a complete line of SF6 recovery and test equipment, from full sized gas reclaimers down to small decomposition detectors.

    Get Price
  • High Sensitivity Gas Sensor to Detect SF6 Decomposition

    Gas sensors for detecting SF6 decomposition products have been pursued as low-cost instrumentation for detecting and locating faults in gas-insulated switchgear (GIS).

    Get Price
  • SF6 Gas Decomposed! Best handling practices APC

    • Provide Support to Alabama Power Company on SF6 equipment, • Purchase SF6 Breakers, 15 kV to 500 kV • Manage Alabama Power Company spare SF6 breaker fleet • Provide support to Alabama Power Company’s Substation Maintenance groups, Substation support group, Substation Construction, Safety and Training organizations

    Get Price
  • Hierarchical WO3–NiO microflower for high sensitivity

    Hierarchical WO 3–NiO microflower for high sensitivity detection of SF 6 decomposition byproduct H 2S Zhijie Wei1, Qu Zhou1,3 and Wen Zeng2,3 1College of Engineering and Technology, Southwest University, Chongqing 400715, People’s Republic of

    Get Price
  • Highly-efficient conversion of SF6 via an eight-electron

    Abstract. Li-SF 6 battery has been proposed as a novel energy conversion device for both reducing greenhouse-effect SF 6 and potentially providing large specific energy. However, the real discharge process of SF 6 remains ambiguous with fast cathode passivation and large polarization. Here we report that the Li-SF 6 chemistry is able to deliver an unprecedented capacity of 20,000 mA h g c−1 with reduced polarization and excellent rate capability by using a low-cost, high-surface-area

    Get Price
  • SF6 gas transfer unit AGTU - Amperis

    Designed as a low cost solution to recovering, consolidating and transferring Sulfur Hexafluoride, the AGTU is an essential tool for servicing small volume SF 6 equipment. Features: Rugged steel enclosure; Regulated inlet for direct connection to high-pressure bottles without throttling; High discharge pressure for liquefaction in high ambient temperatures

    Get Price
  • Decomposition Characteristics of SF6 under Flashover

    In this paper, the flashover discharging experiment was carried out on epoxy resin surface in an SF6 atmosphere under pin-plate electrodes, with the electrodes distance from 5 mm to 9 mm. The concentration of seven characteristic gases was detected, indicating that the concentration of SOF2 and CF4 was the two highest, followed by SO2, CO2, SO2F2, CS2, and H2S. Based on the changes in the

    Get Price
  • Sulfur Hexafluoride (SF6) In Transmission and Distribution

    NV1756 is a 500kVA SF6 Breaker (B1010) SF6 during the calendar year for 2003 it had a total of 6 work orders and 629 lbs. Manufacture date is 1974. 2 130 Attempted to repair in 2004. approx. $15,000 $401,000 shared utility costs APS costs =$98,924 CH556 is a 500kVA SF6 Breaker (B1216) Had a total of

    Get Price
  • SF6 GAS TRANSFER UNIT - GTU SPECIFICATIONS

    Designed as a low cost solution to recovering, consolidating and transferring Sulfur GTU is an essential tool for servicing small volume SF 6 equipment. APPLICATIONS: Recover SF 6 gas to an optionally available auxiliary storage tank Pressure regulated recharging of SF 6 gas to switch gear Consolidation of storage cylinders

    Get Price
  • (PDF) Monitoring of Circuit Breakers using Ion Mobility

    If partial discharge occurs in GIS, SF 6 gas molecules firstly decompose into some low-fluorine sulfides and then react with trace oxygen and water vapor to generate various kinds of decomposition...

    Get Price
  • Competitive adsorption of SF6 decompositions on Ni-doped ZnO

    Jun 15, 2019 · Therefore, in this paper, Ni-doped ZnO (100) surface model was established and the adsorption performances of three typical SF 6 decomposition gases SO 2, SOF 2, SO 2 F 2 on the sensing surface were discussed. Through the DFT method, the geometric structures, adsorption energy, charge transfer, band structure and density of state were calculated.

    Get Price
  • Automation and System Control - Synecom

    The participation in Cmsyn srl, a company whose 50% is held by Synecom, enables us to operate as a System Integrator by performing design, implementation and commissioning of Fire and Gas / ESD systems and automation systems for industry and for Oil Gas applications.

    Get Price
  • Comparative Study of Materials to SF6 Decomposition

    In order to judge the inside insulation fault of SF6 insulated equipment, the gas-sensing properties to a series of characteristic SF6 decomposition components, SOF2, SO2F2, SO2, H2S, CF4, HF, and SF6, have been studied. In this study, a comparative study of these gas-sensing materials has been made in theoretical and experimental fields to find the optimal gas-sensing material, and put

    Get Price
  • Gas-sensing properties of Ptn-doped WSe2 to SF6 decomposition

    Mar 05, 2021 · In order to detect the SF 6 decomposition products, transition metal Pt cluster doping was chosen to enhance the adsorption property of intrinsic WSe 2 monolayer. The adsorption of SO 2 , SOF 2 and SO 2 F 2 on Pt n (n = 1–3) doped WSe 2 monolayer is studied based on the first-principle calculation.

    Get Price
  • SF6 Transfer Procedure for MI-31 - Fermilab

    After Transfer: Pelletron pressure = 75 psig @ 27 °C, Storage pressure = 8 psig @ 35 °F. Close all four SF6 transfer skid LCW supply valves back to the closed position. Transfer is complete III. Transfer of SF6 Gas from Pelletron Tank to Storage Tank. Before starting the procedure, make a status entry in the E-Cool E-log.

    Get Price
  • SYNECOM SRL, Gases, compressed and liquefied, Energy

    Synecom srl is specialised in selling systems and equipment for SF6 gas and alternative gases with a sulphur hexafluoride regeneration service. Designing and manufacturing pyrolysis plants for biomass energy, building HV-MV electric power stations and conventional and renewable energy centres.

    Get Price
  • Adsorption Behavior of Ni-Doped ZnO Monolayer upon SF6

    Sep 06, 2020 · In this article, Ni-doped ZnO (Ni-ZnO) monolayer is proposed as a potential sensing material for detection of two SF6 decomposed components (namely, SO2 and SOF2), based on the density functional theory (DFT) method, to monitor the operation status of SF6 insulation devices in the power system. The Ni-doping effect on the physicochemical properties of the pure ZnO monolayer is first studied

    Get Price
  • Adsorption of SF6 Decomposed Products over ZnO(101̅0

    We carried out a density functional theory study to investigate the adsorption behavior of four kinds of SF6 decomposed products over the ZnO(101̅0) surface. The effects of O and Zn vacancies on the surface were also considered. For perfect ZnO(101̅0) surface, the adsorption of SO2 and H2S exhibits stronger chemical interactions compared to the adsorption of SOF2 and SO2F2. For SO2 and H2S

    Get Price